设置继电器点动时长
通过 device.operation.execute 设置指定继电器的点动持续时长。
权限
text
device:configRequest
json
{
"type": "request",
"requestId": "req_jog_config_001",
"topic": "device.operation.execute",
"data": {
"deviceId": "abc123456789",
"idempotencyKey": "idem_jog_config_001",
"operation": {
"name": "device.relay.jogConfig.set",
"params": {
"relayIndex": 1,
"durationSec": 2
}
}
}
}| 字段 | 类型 | 必填 | 说明 |
|---|---|---|---|
relayIndex | integer | 是 | 继电器序号,从 1 开始 |
durationSec | integer | 是 | 点动时长,范围 1 到 8000 秒 |
Reply
json
{
"type": "reply",
"requestId": "req_jog_config_001",
"code": "COMMAND_ACCEPTED",
"message": "Command accepted.",
"data": {
"command": {
"id": "cmd_01JA...",
"deviceId": "abc123456789",
"operation": "device.relay.jogConfig.set",
"status": "SUCCESS",
"params": {
"relayIndex": 1,
"durationSec": 2
},
"result": {
"relayIndex": 1,
"durationSec": 2
},
"createdAt": "2026-07-15T08:30:00Z"
}
}
}params 是请求值。只有设备确认成功时才返回 result。点动配置变化不会广播 WebSocket 配置事件;如需确认当前配置,调用 REST 查询设备配置。
可能返回 INVALID_REQUEST、AUTH_SCOPE_DENIED、DEVICE_NOT_FOUND、DEVICE_BUSY、DEVICE_OFFLINE、IDEMPOTENCY_CONFLICT、COMMAND_REJECTED、RATE_LIMITED、GATEWAY_UNAVAILABLE 或 INTERNAL_ERROR。