Skip to content

设置继电器点动时长

通过 device.operation.execute 设置指定继电器的点动持续时长。

权限

text
device:config

Request

json
{
  "type": "request",
  "requestId": "req_jog_config_001",
  "topic": "device.operation.execute",
  "data": {
    "deviceId": "abc123456789",
    "idempotencyKey": "idem_jog_config_001",
    "operation": {
      "name": "device.relay.jogConfig.set",
      "params": {
        "relayIndex": 1,
        "durationSec": 2
      }
    }
  }
}
字段类型必填说明
relayIndexinteger继电器序号,从 1 开始
durationSecinteger点动时长,范围 18000

Reply

json
{
  "type": "reply",
  "requestId": "req_jog_config_001",
  "code": "COMMAND_ACCEPTED",
  "message": "Command accepted.",
  "data": {
    "command": {
      "id": "cmd_01JA...",
      "deviceId": "abc123456789",
      "operation": "device.relay.jogConfig.set",
      "status": "SUCCESS",
      "params": {
        "relayIndex": 1,
        "durationSec": 2
      },
      "result": {
        "relayIndex": 1,
        "durationSec": 2
      },
      "createdAt": "2026-07-15T08:30:00Z"
    }
  }
}

params 是请求值。只有设备确认成功时才返回 result。点动配置变化不会广播 WebSocket 配置事件;如需确认当前配置,调用 REST 查询设备配置

可能返回 INVALID_REQUESTAUTH_SCOPE_DENIEDDEVICE_NOT_FOUNDDEVICE_BUSYDEVICE_OFFLINEIDEMPOTENCY_CONFLICTCOMMAND_REJECTEDRATE_LIMITEDGATEWAY_UNAVAILABLEINTERNAL_ERROR

Docs buildVersion v1.3.6-20260720-180213-70
Copyright © 2026 WLTE